Solvent-free, very low emission, fiber-reinforced wet-bed dispersion adhesive for installation of rubber floor coverings of up to 4.0 mm thickness in lengths and tiles (not suitable for special or special-purpose coverings), designer coverings in plank and tile format and for homogeneous/heterogeneous PVC/CV floor coverings. The addition of reinforcing fibers minimizes adhesive billowing during installation and residual indentation in installed flooring. Thanks to its antimicrobial properties, Okatmos® star 110 also helps to prevent odors.

The substrate must be inspected in accordance with VOB Section C, DIN 18365 and the current state of technology and be ready for laying. Substrates are to be pre-treated in accordance with the current BEB datasheet ‚Beurteilen und Vorbereiten von Untergründen‘ (Evaluation and Preparation of Substrates) and TKB Datasheet 8. Depending on the type of substrate and its subsequent load follow requirements regarding primers, patching or self-leveling compounds. With absorptive substrates, apply with a trowel to a thickness of at least 2 mm, with non-absorptive substrates at least 3 mm. Then allow the self-leveling or patching compound to dry sufficiently. The technical datasheets of the other products used are to be complied with. A system assembly must be ensured.

Stir Okatmos® star 110 well before use. Apply the adhesive to the substrate using trowel attached to the lid. Only apply as much to the surface as can be covered within the stated installation time. The trowel should be replaced relatively short time (approx. every 15 - 20 m2) before channels will appear between the fibers and to ensure that the correct amount of adhesive is applied at all times. After the skin over time (depending on the internal climate conditions), install the floor covering in the adhesive bed while still wet, without trapping any air, and rub on carefully. After approximately 30 minutes, rub or roll over the covering again. Ensure that the rear side of the covering is sufficiently wet. The floor covering must be tension-free and lie flat. Weigh down if necessary. Avoid bulging in the area of seams and upwardly projecting building components. Wait at least 24 hours before sealing joints or welding seams in the floor covering. The laying instructions of the manufacturer of the floor covering are to be observed at all times.

Color

beige

Application

interior only

Suitable for chair castors (DIN EN 12529)

suitable

Minimum floor temperature

+17 °C (63 °F)

Skin over time* / Tack time

approx. 5-10 minutes

Open time (working)

approx. 20 minutes

Walkable* / ready for installation*

after approx. 24 hours

Final strength*

after approx. 72 hours

Floor heating system

suitable

GISCODE

D1 according to TRGS 610

EMICODE

EC 1Plus according to GEV

Storage

store at a dry place for up to 12 months

at 68 °F (+20 °C) and 65% relative humidity. Higher temperature and low humidity decreases, lower temperature and high humidity increases this value respectively.

Tooth typetype of floor coveringCoverage
TKB A2Rubber floor coverings of 2 - 4 mm thickness in lengths and tiles with polished rear sideca. 250-280 g/m²
   

Clean tools with water immediately after usage.

Product descriptionItem no.Item no.
33 x 14 kg plastic buckets800984015705800981

The aforementioned information, especially the proposals for processing and utilizing our product, is based on our knowledge and experience. We recommend that you carry out your own tests in every case to ensure the suitability of our products for the intended process and processing purposes because of the different materials and the working conditions which lie beyond our area of influence. No liability can be derived from this advice or from verbal advice, unless we are responsible for (criminal) intent or gross negligence in this respect.